BIYONX RO MEMBRANE
Minimum Order Quantity: 1 Piece
Product Brochure
| Capacity | 8040 |
| Membrane Length | 8040 |
| Membrane Material | Polyamide |
| Automation Grade | Manual |
| Pressure | 150psi (10bar) |
| TDS | 1500+ Tds |
| Salt Rejection | 99.6% |
| Diameter | 6 inches |
| Brand | BIYONX |
The Biyonx 80x40 (8040) RO Membrane is engineered for large-scale water purification systems, offering high permeate flow and excellent salt rejection efficiency. Built with advanced thin-film composite (TFC) technology, it ensures stable operation, long service life, and reduced fouling, even under challenging feed water conditions.
Key Features:
-
�� High Rejection Efficiency: Removes up to 99.5% of dissolved salts, heavy metals, and organic impurities.
-
⚙️ High Flow Capacity: Provides up to 10,000–12,000 GPD (gallons per day), suitable for industrial RO plants.
-
�� Robust Construction: 8-inch diameter × 40-inch length (8040) standard size — fits all major industrial housings.
-
�� Superior Permeate Quality: Ensures consistent and safe output water quality for process, drinking, or reuse applications.
-
�� Durable & Reliable: Optimized anti-fouling design extends membrane lifespan and reduces maintenance costs.
-
♻️ Energy Efficient: Operates effectively at low feed pressure, reducing energy consumption and operational expenses.
Technical Specifications (Typical):
-
Model: Biyonx 8040 RO Membrane
-
Type: Thin Film Composite (TFC) Polyamide
-
Salt Rejection Rate: 99.5%
-
Permeate Flow Rate: 10,000–12,000 GPD (at 225 psi, 25°C, 2000 ppm NaCl)
-
Operating Pressure: 150–600 psi
-
Maximum Feed Water TDS: Up to 5,000 ppm
-
pH Range (Continuous Operation): 2 – 11
-
Max Feed Water Temperature: 45°C
-
Dimensions: 8" × 40" (Standard Industrial Size)
Applications:
✅ Industrial RO Plants
✅ Commercial Water Treatment Systems
✅ Bottled Water Plants
✅ Food & Beverage Industry
✅ Textile, Pharma & Process Water
Additional Information:
- Item Code: 101
- Production Capacity: 1000 LPH
- Delivery Time: IMMEDIATELY
- Packaging Details: BOX
RO Membrane Commercial
Product Brochure
| Capacity | 1000 lph |
| Membrane Length | 8040 |
| Membrane Material | Polypropylene |
| Automation Grade | Manual |
| Pressure | 150 |
| Material | PVC |
| Usage/Application | Industrial |
| Specifications | |
| Brand | Axeon |
| Type | Sea-Water |
| Average NaCl rejection percentage | 99.10 % |
| Minimum NaCl rejection percentage | 98.60 % |
| Average MgSO4l rejection percentage | >99.1 % |
| Max Pressure kPa | 6894.8 |
| Max Pressure psi | 1000 |
| Max Pressure bar | 69 |
| Max Temperature °C | 45.0 |
| Max Temperature °F | 113 |
| Membrane Active Area ft2 | 300 |
| Membrane Active Area m2 | 27.8 |
| Flow gpd | 6000 |
| Flow m3/day | 22.6 |
Dimensions / Weights |
|
| Length in inch | 40 |
| Length in cm | 101.6 |
| Carton shipping weight in lbs | 37.5 |
| Carton shipping weight in kg | 17.0 |
H2O RO Tech Membrane
Minimum Order Quantity: 1 Piece
Product Brochure
| Material | Poly Amide |
| Membrane Length | 10 mm |
| Membrane Material | Polyamide |
| Automation Grade | Automatic |
| Pressure | 150psi (10bar) |
| TDS | 1500+ Tds |
| Maximum Operating Temperature | 60-65 DegreeC |
| Operation PH | 8-10 |
Applications
- Municipal drinking water, Industrial process water, Water reuse
Operating Information
- Please consult the latest H2O technical bulletin, design guidelines, computer design program, or call an application specialist for the recommended design range. Not strictly following the operating limits stated in this bulletin will void and nullify the Limited Warranty.
- All RO elements are wet tested treated with a 1 percent by weight sodium bisulfite storage solution. Afterwards, the RO elements are vacuum packed in oxygen barrier bags or treated with a tested feed water solution, and then vacuum sealed in oxygen barrier bags with deoxidant inside. Toray recommends flushing H2O RO elements for 30 to 60 minutes once every two days with sufficient quality flushing water, such as pre-treated feed water, to prevent biological growth during system shutdown. Please refer to the H2O RO Handling Manual for suggested flushing water quality.
- The presence of free chlorine and other oxidizing agents under certain conditions, such as heavy metals that act as oxidation catalysts in the feed water, will cause unexpected oxidation of the membrane. H2O strongly recommends removing these oxidizing agents contained in feed water before operating the RO system.
- Permeate from the first hour of operation shall be discarded.
- The customer is fully responsible for the effects of chemicals that are incompatible with the elements. Their use will void the element Limited Warranty.
- Maximum operating pressure will vary depending on feed temperature. Please ask for detailed information from H2O RO Tech if needed.
Ro Domestic Membrane
| Membrane Diameter | 10 inches |
| Maximum Chlorine Concentration | 80gpd |
| Feed Water Temperature | 80gpd |
| Membrane Length | 10inche |
| Membrane Material | Polypropylene |
| Automation Grade | Manual |
Residential Purpose for water treatement.
Additional Information:
- Production Capacity: 10lph